Skip to content
Plexus Electrical

Heating & cooling

Ducted vs high-wall heat pumps: which suits your home?

Ducted heat pumps heat and cool the whole home through ceiling outlets. High-wall units heat one space. Compare cost, comfort, looks, noise and running costs.

By Plexus ElectricalPublished Updated 8 min read

A high-wall heat pump heats and cools the room it is in, and does it well at a lower upfront cost. A ducted heat pump heats and cools the whole home from one hidden indoor unit, with outlets in each room, at a higher upfront cost. If you mainly want a warm living area, a high-wall is usually the sensible choice. If you want every room comfortable, nothing on the walls, and you have the ceiling space, ducted is worth pricing.

How each system works

High-wall (single split). One indoor unit mounted high on an interior or exterior wall, one outdoor unit, connected by refrigerant pipes, power and communication cables, and a condensate drain. EECA describes single-split systems as easy to install and cost effective, with one outdoor unit connected to an indoor unit that heats one room.

Ducted. An indoor fan-coil unit concealed in the ceiling space (or under the floor), insulated supply ducts to outlets in each room, a return-air grille with a filter, an outdoor unit, and a wall controller. EECA calls ducted systems "central heating for your whole house" and notes they can be more expensive upfront. Zoning adds motorised dampers so rooms can be controlled separately.

Side-by-side comparison

High-wall Ducted
Rooms served One room or open-plan space Whole home, or a group of rooms
Upfront cost Lower Higher
What you see inside The wall unit Ceiling outlets and a return grille
Heat distribution Strongest near the unit, can miss corners or adjoining rooms Air delivered to each room
Control Remote per unit Wall controller; room-by-room with zoning
Efficiency No duct losses Some duct losses (Consumer NZ: slightly less efficient)
Install disruption Simpler, less time on site More time in the ceiling space; easiest in new builds and renovations
Space needed Wall space and an outdoor unit position Ceiling or subfloor space for the unit and ducts
Filter cleaning On the unit, high on the wall One return-air filter, usually in a ceiling grille
If it fails That room loses heating Whole system is out until fixed

Comfort and heat distribution

A high-wall unit is very effective in the room it is in. It struggles to push heat down a hallway into bedrooms, and the room may be warm near the unit and cooler at the far end of a long open-plan space. Level notes a unit in a corner may only partly heat or cool the room, which is why position matters so much. See where to install a heat pump.

A ducted system sends conditioned air to every room with an outlet, so bedrooms are warm at bedtime and the house is a more even temperature. Without zoning, it heats every room at once from one thermostat. With zoning, you can turn rooms off or set them to different temperatures. Mitsubishi Electric notes its ZoneIQ zoning does not heat and cool simultaneously, and the same applies to any single ducted system: it has one indoor coil, so the whole system is either heating or cooling at any one time.

Looks

This is often the deciding factor. Consumer NZ says ducted systems have the least visual impact of any heat pump system, just small flush vents in each room. A high-wall unit is a visible appliance on the wall, and you need somewhere sensible to put it.

Efficiency and running costs

For one room, a high-wall unit is the more efficient choice: no ducts, no losses. Level warns ducted systems can lose more than 30 % of their heating energy if ducts are overlong, have many bends or run through uninsulated space, so duct design and insulation matter.

In real life, a ducted system usually costs more to run in total because it is heating more of the house. Whether that is a cost or a benefit depends on whether you want those rooms heated. Zoning is the main way to control it. See heat pump running costs.

Upfront cost

A high-wall install is the lowest-cost way to get efficient heating into a room. EECA gives a typical figure of around $4,400 including purchase and installation. Ducted systems cost considerably more because of the ductwork, design and labour. Our guides to heat pump installation cost and ducted heat pump cost explain what drives each price.

Which suits which home

A high-wall is usually the right choice if:

  • you mainly want to heat the living area;
  • the home is a smaller house, townhouse or apartment;
  • there is little or no ceiling space (skillion roof, concrete slab ceiling);
  • budget is the main constraint;
  • you want to meet the Healthy Homes heating standard in a rental's main living room at the lowest cost (see Healthy Homes heating and heat pumps).

Ducted is worth pricing if:

  • you want bedrooms and living areas comfortable, not just one room;
  • you are building or renovating, so the ceiling is accessible;
  • you do not want units on the walls;
  • the home is larger, and several high-walls would be needed anyway;
  • you want summer cooling throughout, particularly if large north- or west-facing glazing, upstairs bedrooms under the roof or sunny open-plan living make cooling the bigger load.

Insulate first if the house is cold and draughty. Level notes heat pumps do not replace the need for good insulation. Insulating first reduces the size and running cost of whichever system you choose.

Somewhere in between: a multi-split connects several indoor units to one outdoor unit, each with its own controller. Compare the options in multi-split vs ducted heat pumps.

Why ducted suits new builds and renovations

Ducted makes most sense when the ceiling is open anyway. Ducts, refrigerant pipes and cables go in before linings and cladding, the indoor unit position and outlet layout are planned with the floor plan, and the electrical supply is designed in from the start rather than added later. A heat pump outdoor unit usually needs its own dedicated circuit, so the switchboard needs a spare way and enough capacity for it. Plexus produces its own electrical plans for new build electrical work, so the heat pump circuit, switchboard space and the rest of the house's load are planned together. In an existing home, an electrician should check the board first; see switchboard upgrades if it is old or full.

How to compare using the calculators

  1. Run the heat pump size calculator for your main living area. If it suggests a high-wall at a sensible size, that is your baseline option.
  2. Run the room-by-room calculator with every room you would want heated. It gives each room's load, the share of airflow each room would need, and a total ducted capacity.
  3. If the single-room result is above 8 kW, the calculator itself suggests two units or ducted, because one wall unit will struggle to spread that much heat evenly.

As an illustration, a hypothetical five-room new build entered into the room-by-room calculator (a 55 m² north-facing open-plan living area with large glazing, three bedrooms and a study, 2.4 m ceilings, Auckland) came out at 11.17 kW heating and 9.81 kW cooling for a ducted system, with the living area taking about 57 % of the airflow. A single high-wall sized for that living area alone would leave the bedrooms unheated.

If you choose ducted: getting it right

The design decisions below make the difference between a ducted system you love and one you put up with. Each one is also a fair question to put to an installer before you sign a quote:

Decision What to ask the installer
Size it room by room, not from floor area alone How was the capacity worked out, and can I see the room-by-room loads?
Zone it to how you live (bedrooms and living areas in separate zones is a common start) How many zones are included, and which rooms are in each? See how ducted zoning works.
Keep duct runs short and insulated, which is where efficiency is won or lost How long is the longest duct run, and how are the ducts insulated?
Position the return-air grille carefully, because it affects airflow, noise and filter cleaning Where will the indoor unit, each outlet, the return-air grille and the outdoor unit go?
Plan the electrical supply What electrical work is needed, and is my switchboard suitable?
Plan service access to the indoor unit How will the system be commissioned and the airflow to each room balanced, and what servicing does the manufacturer expect to keep the warranty valid?

Ventilation is a separate question. A ducted heat pump recirculates indoor air; it does not bring in fresh air or replace extractor fans. If the house is airtight or prone to condensation, see HRV vs positive pressure ventilation.

Clear answers to these questions are a good sign the system has been designed for your house rather than picked from a floor area.

Limitations

The calculators give a preliminary capacity, not a design. Whether ducted is practical depends on your roof structure, ceiling space, where the outdoor unit can go and your switchboard capacity, which needs a site visit to confirm.

Next steps

Sources

  1. EECA: Choose an efficient heat pump for your home
  2. Consumer NZ: Heat pump buying guide
  3. Level (BRANZ): Heat pumps
  4. Level (BRANZ): Heat pump configuration and installation
  5. Mitsubishi Electric NZ: ComfortMaster ducted with ZoneIQ
  6. Tenancy Services: Heating standard

This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.

FAQ

Frequently asked questions

Is ducted or high-wall more efficient?

Like for like, a high-wall unit heating one room is usually a little more efficient, because there are no duct losses. Consumer NZ notes ducted systems are slightly less efficient for that reason. In practice the bigger factor is how much of the house you heat and for how long.

Can I add a ducted system to an existing house?

Often, if there is a usable ceiling space or subfloor for the indoor unit and ducts. Low-pitched or skillion roofs, and some two-storey layouts, make it harder. A site visit confirms what will fit.

Can I start with a high-wall and go ducted later?

Yes. Many homes start with a high-wall in the main living area. If you are planning a renovation, that is a good time to consider ducted, because the ceiling may be opened up anyway.

Which is quieter?

With a ducted system the indoor unit is in the ceiling space, so what you hear in the room is mainly air through the outlets. A high-wall unit's fan is in the room, although modern units are quiet at low speed. The outdoor unit makes similar noise either way.

Is ducted air conditioning worth it?

It is worth it if you want every room comfortable year-round, you do not want units on the walls, and the house has usable ceiling or subfloor space. It is usually not worth it if you only need to heat one living area, there is no space for the ducts, or the budget would do more good spent on insulation first.

Does a ducted heat pump bring in fresh air?

No. Level (BRANZ) notes most heat pump systems only recirculate room air and do not supply fresh air, so ventilation needs to be handled separately, for example with extractor fans or a heat recovery ventilation system.

Can ducted heating meet the Healthy Homes standard?

Tenancy Services says central heating meets the heating standard if it provides heat directly to the main living room, for example through vents or ducts, and meets the required heating capacity. The capacity still needs to be checked with the Tenancy Services method.

Does ducted air conditioning add value to a house?

We cannot give you a figure, and we would be wary of anyone who does. What we can say is that whole-home heating and cooling is a feature buyers can see and use, and it is far easier to install during a build or renovation than afterwards.

How long does a heat pump system last?

EECA lists a lifespan of about 15 years for heat pump technology, whether ducted or high-wall. Regular servicing and filter cleaning help a system reach that.

Get a quote

Tell us about your project.

Whether it is one power point or a fifteen-home development, the quickest way to an accurate quote is a few details and, if you have them, photos or plans.

Call 021 210 5934Request a quote