Heat pump calculator
Room-by-room heat pump calculator
Add each room for its own heating and cooling load, the share of airflow it needs, and the total capacity for a ducted or multi-room system. The most detailed of our three calculators.
- Up to 20 rooms
- Heating, cooling and airflow
- 5 to 10 minutes
- Saves on your device
Room-by-room heat pump calculator
Other calculators: Single room / Whole home / System selector
Who it is for
Planning a ducted or multi-room system
Use this when you are building, renovating or seriously considering a ducted system or a multi-split. Different rooms need very different amounts of heating and cooling: a sunny west-facing lounge and a south-facing bedroom are not the same.
The airflow share is how a ducted system's air is divided between rooms. It uses whichever is larger for each room, heating or cooling, so a sun-loaded room still gets enough air in summer.
Before you start
What you will need
- Width and length of each room (or its volume for odd shapes)
- Ceiling heights, if they differ from 2.4 m
- Insulation level, which can differ room to room in renovated homes
- Your region
- Optional for each room: window area and direction
Reading your result
What the numbers mean
Heating capacity (kW)
The heat output to look for on a heat pump's specification as its rated heating capacity. Choose a unit rated at or above this figure.
Cooling capacity (kW)
The cooling output to check against the rated cooling capacity. Rated cooling is usually about 89% of rated heating, so in sunny rooms cooling can decide the size.
Not electricity use
These are thermal figures. A heat pump moves heat rather than making it, so it delivers several kW of heat for every kW of electricity it draws. Running cost depends on that efficiency, your tariff and how you use it.
The method
How the calculation works
The same engine runs in CertMate, the trade software Plexus uses on site. Every step is shown under Show working on your result.
- 1. Volume
- Floor area multiplied by ceiling height. A high ceiling means more air to heat.
- 2. Heat loss rate
- A watts-per-cubic-metre figure for the insulation level, calibrated against Mitsubishi Electric's published heat pump selector for Auckland rooms, with extra headroom built into the whole-home and room-by-room rates because one ducted unit serves every room. Large glazing adds 15%; a south-facing room adds 10% to heating.
- 3. Climate
- Each of 27 NZ regions has a winter design temperature taken from Mitsubishi Electric NZ's selector. Heat pumps lose output as it gets colder outside, so the figure is scaled by how much capacity a typical unit keeps at your design temperature, compared with Auckland.
- 4. Margin
- A 2.5% safety margin covers ordinary variation. More margin is not better: an oversized heat pump cycles on and off, which is less efficient and less comfortable.
- 5. Cooling
- Calculated separately: heat coming through the building at your region's summer design temperature (NIWA data), sun through the windows for their direction, and the heat from people and appliances. Cooling has no regional derate because units are rated for cooling at 35 °C outdoors.
FAQ
Room-by-room heat pump calculator: questions
Does the room-by-room total match the whole-home calculator?
They use the same heat loss rates and the same recommendation step, so an equivalent house gives the same answer either way. Room by room is more accurate because each room's size, glazing and direction count separately.
Which rooms should I include?
Every room that will have an outlet or an indoor unit. Leave out garages, laundries and storage. Treat open-plan kitchen, dining and living as one room.
Is my information saved?
Only on your own device, so you can come back and finish later. Nothing is sent to us unless you choose to request a quote.
Can I use the room figures for separate heat pumps?
Yes, as a starting point. Each room's heating figure is a guide for a high-wall or multi-split indoor unit in that room.
Can I get a quote from my result?
Yes. Select Get a quote based on my results and every room goes into the quote form with its figures.
Installing in Auckland?
The calculators work anywhere in New Zealand. Plexus Electrical installs, wires and services heat pumps across Auckland, from the Hibiscus Coast to Papakura. See our service areas.
Related
Keep exploring
Services and tools