Skip to content
Plexus Electrical

Heating & cooling

Ducted heat pump cost in NZ: what drives the price

What a ducted heat pump costs depends on capacity, ducting, zoning, access and electrical work. Learn every cost driver and how to compare quotes properly.

By Plexus ElectricalPublished Updated 6 min read

A ducted heat pump costs more than a single wall unit because you are paying for a whole-home system: a larger indoor unit in the ceiling, insulated ductwork to every room, outlets, a return-air grille, controls and often zoning, plus the design and labour to fit it. EECA notes ducted systems "can be more expensive upfront than the other options", and Consumer NZ describes them as expensive to install. The final figure for your home depends on a handful of cost drivers, which this guide explains so you can read and compare quotes properly.

We have not put a price range here because a number without your house behind it is not much use. If you want a ballpark, the whole-home calculator gives you the system capacity, which is the starting point for any quote.

What you are paying for

A ducted system has more parts than people expect:

Component What it does
Indoor fan-coil unit Sits in the ceiling space (or under the floor) and heats or cools the air.
Supply ducts Insulated ducts carrying air from the unit to each room.
Outlets Ceiling (or floor) diffusers in each room.
Return-air grille and filter Draws air back to the unit. The filter needs regular cleaning.
Outdoor unit Connected to the indoor unit by refrigerant pipework and cabling.
Wall controller Sets mode, temperature and timers.
Zoning (optional) Motorised dampers, a zone controller and sensors for room-by-room control.
Electrical supply A suitable circuit from the switchboard, isolation and a Certificate of Compliance.

The cost drivers

1. System capacity

The bigger the home's heating and cooling load, the bigger (and more expensive) the indoor and outdoor units. Capacity is driven by floor area, ceiling height, insulation, glazing and climate. A well-insulated new build needs less capacity than an older home of the same size. Run the room-by-room calculator to see which rooms drive the total.

2. Number of outlets and duct runs

Each room served adds a duct run, an outlet and labour. Long runs and tight bends also matter for performance: Level notes ducted systems can lose more than 30 % of their heating energy if ducts are overlong, have many bends or run through uninsulated space. A good design keeps runs short, which can affect where the indoor unit goes.

3. Ceiling space and access

This is often the biggest variable in an existing home. Questions that change the price:

  • Is there enough height in the ceiling space for the indoor unit and ducts?
  • Is the roof low-pitched or skillion, with little or no space?
  • Can the unit be lifted in through the existing access hatch, or does a new opening need to be made and made good? (Some manufacturers offer models that split into two parts for access.)
  • Is there existing insulation that has to be moved and replaced?

4. Single or two storey

Serving an upper floor from one ceiling space, or serving a ground floor in a two-storey home, may need ducts routed through cupboards or floor voids, or a second system. This adds design time and labour.

5. Zoning and controls

An unzoned system heats or cools every room at once from one thermostat. Zoning adds motorised dampers, a zone controller and usually a sensor per zone. Mitsubishi Electric's ZoneIQ, for example, supports up to 10 zones. More zones means more cost, but also more control. See how ducted zoning works.

6. Outdoor unit position and pipe run

A short, direct pipe run between indoor and outdoor units is cheaper and more efficient. Longer runs, extra height, roof mounting, or brackets on a two-storey wall add materials and labour, and may need extra refrigerant charge.

7. Electrical work

A ducted heat pump needs an appropriate dedicated circuit and an isolating switch. If your switchboard is full, old, or the supply is already heavily loaded (for example with an EV charger), you may need switchboard work. Because Plexus is one team for electrical and heating and cooling, the electrical side can be assessed at the same visit as the heat pump design.

8. Condensate drainage

The indoor unit produces water when cooling (and the outdoor unit when heating). If it cannot drain by gravity to a suitable point, a condensate pump is needed.

9. New build or retrofit

In a new build, ducts, pipework and cables can go in before the linings and cladding, coordinated with other trades. In a retrofit the installer works around what is there. See our new build electrical and ducted air conditioning pages for how we coordinate on new homes.

10. Site conditions

Coastal sites may call for corrosion-protected outdoor units. Body corporate approval may be needed in a unit title property. Removal of an old system, scaffolding or difficult access all add cost.

What a good ducted quote should include

Ask for these in writing so you can compare like with like:

  • Indoor and outdoor model numbers, with rated heating and cooling capacity in kW.
  • How the capacity was worked out: a room-by-room load, not just floor area.
  • A layout: where the indoor unit, each outlet, the return-air grille and the outdoor unit go.
  • Duct type and insulation, and how far the longest run is.
  • Zoning details: number of zones, which rooms are in each, and the controller model.
  • Electrical scope: the new circuit, isolating switch, any switchboard work, and the Certificate of Compliance and Electrical Safety Certificate.
  • Pipe length included, and what happens if more is needed.
  • Condensate arrangement: gravity drain or pump.
  • Making good: ceiling openings, insulation reinstatement, outdoor unit mounting.
  • Commissioning: airflow balanced to each outlet, and a record of the settings.
  • Warranty: the manufacturer's warranty terms for that model (they vary by brand and product) and any workmanship warranty, in writing.
  • Price including GST, and anything excluded.

How to compare ducted quotes

  1. Line up the capacities. A lower price on a smaller unit is not a saving if it cannot hold temperature in July. If one quote is much smaller than the others, ask why.
  2. Count the outlets and zones. Three zones and seven outlets is a different system to one zone and five outlets.
  3. Check the return air. Ask where the return-air grille goes, how big it is and how easy the filter will be to reach for cleaning.
  4. Look for the electrical line. If it is missing, it is either included or it will be a surprise.
  5. Ask about the controller and Wi-Fi. Some quotes include app control, some list it as an extra.
  6. Compare warranty terms, not just years. Check what the warranty requires, such as servicing records.

Running cost is part of the cost

A ducted system runs on the same principle as any heat pump: electricity in, several times as much heat out. Consumer NZ notes ducted systems are slightly less efficient than other types because of heat loss from the ducts, and that depending on use a very large heat pump (10 kW or more) might cost around $1,000 a year to run. Zoning helps by only conditioning the rooms you use. Our guide to heat pump running costs shows how to estimate yours.

Grants and funding

EECA's Warmer Kiwi Homes programme offers heating grants for eligible owner-occupiers, with the heat pump sized to heat the room it is installed in, not the whole house. Check the current criteria on the EECA site before assuming a ducted system qualifies.

Limitations of any estimate

Until someone has been in your ceiling space, any ducted price is a guess. Roof structure, existing services, insulation, and where the outdoor unit can realistically go all change the scope. That is why we would rather show you the cost drivers than a number that might not hold.

Next steps

Sources

  1. EECA: Choose an efficient heat pump for your home
  2. Consumer NZ: Heat pump buying guide
  3. Level (BRANZ): Heat pumps
  4. Level (BRANZ): Heat pump configuration and installation
  5. Mitsubishi Electric NZ: ComfortMaster ducted with ZoneIQ
  6. EECA: Warmer Kiwi Homes

This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.

FAQ

Frequently asked questions

Why is ducted more expensive than a high-wall heat pump?

A ducted system is a bigger indoor unit plus a network of insulated ducts, ceiling outlets, a return-air grille with filter, a wall controller and often zoning. Most of the extra cost is design and labour in the ceiling space, not just the equipment.

Is it cheaper to install ducted in a new build?

Usually the work is simpler, because ducts, pipework and cabling can go in before the linings and cladding, and the layout can be planned around the system. In an existing home the cost depends heavily on ceiling space access, roof pitch and how many outlets are needed.

Does a ducted system need a switchboard upgrade?

Not always. It needs a suitable dedicated circuit, and whether your existing switchboard and supply can take it depends on what is already connected. This should be checked as part of the quote, with any electrical work listed as its own line.

Can I get a grant for a ducted heat pump?

EECA's Warmer Kiwi Homes programme funds heat pumps for eligible owner-occupiers, with the unit sized to heat the room it is installed in. Check eligibility and what is covered on the EECA website, as criteria change.

Get a quote

Tell us about your project.

Whether it is one power point or a fifteen-home development, the quickest way to an accurate quote is a few details and, if you have them, photos or plans.

Call 021 210 5934Request a quote