A positive pressure system uses a fan to push filtered air into the house, usually from the roof space or from outside, which raises the indoor pressure slightly so stale air leaks out through gaps, doors and windows. A balanced heat recovery ventilation (HRV) system uses two fans: one brings in fresh outdoor air, the other extracts stale indoor air, and a heat exchanger transfers heat from the outgoing air to the incoming air. BRANZ says a well-designed and commissioned balanced heat recovery system is the best option for whole-house ventilation, but it has the highest upfront cost. Roof-space-sourced positive pressure systems cannot be used to demonstrate compliance with Building Code clause G4, which requires outdoor air.
Why ventilation matters
Ventilation removes moisture and airborne pollutants. Level (BRANZ) puts a healthy ventilation rate at 0.35 to 0.5 air changes per hour, and notes houses built after 2000 are typically much more airtight (around 0.2 air changes per hour on average) than older homes. It cites the 2023 Census finding that 18 % of private occupied dwellings experienced dampness at least some of the time. BRANZ now recommends mechanical ventilation as the default option for new homes.
Ventilation is not air conditioning. A heat pump heats and cools the air already in the room. Level notes most heat pump systems do not include a fresh-air supply and only recirculate room air, so ventilation needs to be handled separately.
How positive pressure systems work
According to BRANZ Bulletin 698:
- A fan brings air into living areas, typically through ceiling-mounted diffusers, creating a slight positive pressure that forces indoor air out through gaps and leakage paths.
- Proprietary systems take either roof space air or outside air. Some that usually use roof space air have a bypass that takes outside air from the eaves in warmer months.
- Some have electric resistance heaters to pre-heat cold incoming air.
- For the system to work, the building must leak enough air to match the supply rate. In very airtight homes, windows may need to be left slightly open or vents installed.
The roof space problem
BRANZ is clear that drawing air from the roof space does not comply with clause G4, which requires ventilation with outdoor air. It also warns that controlling airflow only on temperature difference can mean too little fresh air in colder weather, and that systems should never draw air from roof spaces under claddings where asbestos has been identified.
Level adds that roof space air is often colder than room air on overcast days and at night, and quotes EECA and University of Otago research which found that, most of the time, pumping roof space air into the house provided no heating or cooling benefit and often pushed the indoor temperature further from where it should be.
Systems that take air from outside rather than the roof space avoid the G4 issue, but they still rely on air leaking out of the house and do not recover heat from the air they push out.
How balanced heat recovery works
Level describes HRV as a ducted system with two fans and an air-to-air heat exchanger, usually in the roof space:
- Supply: fresh outdoor air is drawn in, filtered, warmed by the outgoing air in the heat exchanger, and delivered to living rooms and bedrooms.
- Extract: stale, moist air is drawn from wet areas such as kitchens and bathrooms and sent out through the heat exchanger.
- Summer bypass: many units can bypass the heat exchanger to bring in cooler outdoor air.
Level reports a BRANZ trial where the core recovered around 73 % of the heat from outgoing air, in line with the typical 70 % for cross-flow cores, but warns that delivered efficiency can drop below 30 % if duct heat and air losses are not dealt with. BRANZ Bulletin 698 says balancing the extract and intake airflow is critical: a deliberately unbalanced system it tested dropped from 70 % core efficiency to around 40 % overall. Ducts outside the thermal envelope need to be well insulated.
Energy recovery ventilation (ERV)
An ERV is similar but also transfers water vapour between the air streams. Level notes ERVs are useful in very dry environments, but if moisture removal is the goal, a moisture-transfer system should not be specified.
Side-by-side comparison
| Positive pressure (roof space air) | Positive pressure (outside air) | Balanced HRV | |
|---|---|---|---|
| Air source | Roof space | Outside | Outside |
| Extracts stale air | No, relies on leakage | No, relies on leakage | Yes, through its own fan |
| Heat recovery | No | No | Yes, via heat exchanger |
| Building Code G4 outdoor air | Cannot demonstrate compliance (BRANZ) | Uses outdoor air | Meets the outdoor air requirement (Level) |
| Needs | Enough leakage paths for supply air to escape | Enough leakage paths for supply air to escape | At least moderate airtightness, with served spaces heated (BRANZ) |
| Upfront cost | Lower | Lower to moderate | Highest (BRANZ) |
| Ongoing | Filter changes | Filter changes | Filters, core cleaning, annual service |
Which is right for your home?
A balanced HRV makes most sense when:
- you are building new or doing a major renovation, which Level says is when HRV is most cost effective;
- the house is reasonably airtight (new builds and well-sealed renovations);
- the rooms served are heated, so there is heat worth recovering;
- you want ventilation without opening windows, for security or noise.
A positive pressure system may be considered when:
- a lower-cost improvement is the goal;
- it draws outside air rather than roof space air;
- the house has enough leakage paths, or vents, for the supply air to escape;
- extractor fans are already in place in the kitchen and bathrooms.
In every case:
- remove moisture at source first, with extractor fans in kitchens and bathrooms that vent to outside;
- deal with ground moisture under suspended floors (the Healthy Homes standards require a ground moisture barrier where there is an enclosed subfloor);
- insulate, and heat the house to a healthy temperature.
Extractor fans and the Healthy Homes standard
The Healthy Homes ventilation standard requires rental kitchens and bathrooms to have an extractor fan venting to outside, or a qualifying continuous mechanical ventilation system. Fans installed after 1 July 2019 must have a minimum diameter (including ducting) of 150 mm or 50 litres per second for kitchens, and 120 mm or 25 litres per second for bathrooms. Every habitable room also needs openable windows, doors or skylights that total at least 5 % of the room's floor area. A whole-house ventilation system does not replace these requirements unless it meets the specific continuous mechanical ventilation criteria.
Sizing a balanced system
Level gives the basic method from NZS 4303: multiply the internal volume being ventilated by 0.35 air changes per hour. For example, an 80 m² house with an internal volume of 192 m³ needs about 67.2 m³/h. Duct sizing, outlet positions and balancing are then designed around that flow.
Pairing ventilation with a heat pump
A heat pump and an HRV do different jobs and work well together: the heat pump heats and cools, the HRV brings in fresh air while recovering some of the heat. In a ducted heat pump home, the two systems have separate ducts and controls. Planning both at the same time, especially in a new build, makes it easier to route ducts and keep service access. Both also need power from the switchboard, so include the ventilation unit, the heat pump circuit and any new extractor fans in the new build electrical plan rather than adding them once the linings are on.
Maintenance
Level says an HRV should ideally be serviced annually, with owner tasks such as replacing filters every 6 or 12 months, cleaning outside hoods every 12 months, and cleaning the heat exchanger every 12 or 24 months, depending on the manufacturer. Supply systems also need filter changes; Level notes filters in roof space warm air transfer systems commonly need replacing every 12 or 24 months.
Limitations
This is general guidance. The right ventilation system depends on how airtight your home is, where moisture comes from, the roof space and duct routes, and what you are trying to fix. A damp or mouldy house may have a ground moisture, leak or drainage problem that no ventilation system will solve on its own.
Next steps
- Read about our heat recovery ventilation and home ventilation services.
- Planning heating as well? See choosing heating and cooling for an Auckland home.
- Request a quote and tell us about any condensation, mould or stuffiness you are seeing.
Sources
- Level (BRANZ): Air supply ventilation systems
- Level (BRANZ): Heat and energy recovery ventilation systems
- Level (BRANZ): Active ventilation
- BRANZ Bulletin 698: Residential mechanical ventilation systems (PDF)
- Tenancy Services: Ventilation standard
- Level (BRANZ): Heat pumps
- Tenancy Services: Healthy homes standards, what a landlord needs to know