Ducted zoning splits a ducted heat pump's supply ducts into zones, each with a motorised damper that opens, closes or partly closes to control how much conditioned air reaches those rooms. A zone controller reads temperature sensors in each zone and adjusts the dampers so each area holds its own set temperature, or switches off entirely. The heat pump itself is still one system: zoning decides where the air goes, not whether it is warm or cool.
The parts of a zoned ducted system
| Part | Job |
|---|---|
| Indoor fan-coil unit | Heats or cools the air, in the ceiling space or subfloor |
| Supply ducts | Insulated ducts from the unit to each room's outlet |
| Motorised dampers | Fitted in the supply ducts, one per zone; open, close or modulate |
| Zone controller | The "brain" that reads sensors and drives dampers |
| Temperature sensors | In each zone, or in the zone controller and room touchpads |
| Return-air grille | Draws air back through a filter to the unit |
| Outdoor unit | Supplies heating or cooling capacity to the indoor unit |
Without zoning, a ducted system works from a single thermostat. Mitsubishi Electric puts the problem plainly on its ComfortMaster page: a standard ducted system delivers heating or cooling to all rooms at once, whether or not they are in use, which can over-heat or over-cool some rooms and waste energy.
How it works, step by step
- You set a temperature for each zone, or switch zones off, on the controller or an app.
- Sensors report each zone's actual temperature.
- The controller compares each zone with its set point. Zones that need more heat have their dampers opened further; zones already at temperature are throttled back or closed.
- The heat pump adjusts its output to suit the zones that are calling. An inverter heat pump can run its compressor more slowly when only a small part of the house needs heat.
- Schedules change zone set points through the day, for example living areas warm in the evening, bedrooms warm before bedtime.
On Mitsubishi Electric's ZoneIQ, for example, the manufacturer says dampers adjust in 5 % increments, each zone can have its own sensor reporting temperature and humidity, temperatures can be set in 0.5 °C steps, and up to 10 zones are supported. Other brands' zone controllers work on the same principle with different features.
Zoning versus multiple heat pumps
Zoning is not the same as having separate heat pumps in each room:
- One mode for the whole system. You cannot cool the upstairs bedroom while heating the downstairs lounge. If that matters to you, look at multi-split or separate units.
- Shared capacity. All zones draw on one indoor and outdoor unit. If every zone calls for full heat on a cold morning, they share the system's capacity.
- Airflow has limits. A ducted unit is designed to move a certain range of air. When most zones are closed, the system has to cope with much less duct open to it. How that is managed varies by manufacturer and controller, so it is a design question for your installer. Level notes that oversized ducted systems run at higher than necessary pressure, which can cause duct leakage, so matching the unit to the duct network matters.
Common ways to zone a home
| Layout | Zones | Why |
|---|---|---|
| Single-level family home | Living / bedrooms | Living areas in use by day, bedrooms at night |
| Home with a study or media room | Living / bedrooms / study | Heat the study during working hours only |
| Two-storey home | Upstairs / downstairs (or more) | Upstairs often needs more cooling, downstairs more heating |
| Per-room | One zone per room with a sensor each | Maximum control and comfort for different preferences |
Fewer zones means fewer dampers and a simpler, lower-cost system. Per-room zoning gives the most control. A good compromise is zones that match how the house is actually used.
Designing zones with the room-by-room calculator
The room-by-room calculator is a good starting point for zoning. For each room it gives:
- the heating load and cooling load in watts;
- the share of airflow each room needs, which informs outlet size and how zones are balanced;
- the total system capacity.
As an illustration, a hypothetical Auckland new build entered into the calculator (55 m² north-facing open-plan living with large glazing, three bedrooms and a study, 2.4 m ceilings) gave these results:
| Room | Heating load | Cooling load | Share of airflow |
|---|---|---|---|
| Living, dining, kitchen | 6,070 W | 6,320 W | 56.7 % |
| Master bedroom | 1,540 W | 1,450 W | 13.8 % |
| Bedroom 2 | 1,270 W | 510 W | 11.4 % |
| Bedroom 3 | 1,160 W | 480 W | 10.4 % |
| Study | 860 W | 810 W | 7.7 % |
| System | 11.17 kW heating | 9.81 kW cooling |
Two things are useful here for zoning. The living area dominates the load, so it would usually be its own zone. And the south-facing bedrooms need much more heating than cooling, while the living area needs slightly more cooling than heating. A bedrooms zone and a living zone lets each be set to suit.
Getting the most from zoning
- Use schedules. EECA advises heating only when you need it and using timers so the house is warm when you wake or get home (EECA). Zoning lets you apply that room by room.
- Turn off unused zones, such as a guest room, rather than leaving them at temperature.
- Keep set points sensible. EECA recommends 18 to 21 °C for heating.
- Do not close outlets by hand to "zone" a non-zoned system without advice. Changing airflow can affect how the system performs.
- Keep the return-air filter clean so airflow is not restricted. See how often a heat pump should be serviced.
Retrofitting zoning
Adding zoning to an existing ducted system is often possible. It usually involves fitting dampers in the supply ducts, adding a zone controller and sensors, and wiring them into the indoor unit's controls. Whether the existing system is a good candidate depends on how the ducts are laid out (rooms need to be grouped on duct branches that can be dampered), whether the indoor unit and controller are compatible, and the condition of the ducts. This is checked on site.
Smart control and integration
Many zone controllers offer Wi-Fi and app control, and some integrate with home automation systems. If you are planning smart home automation, mention it early so the zone controller can be chosen to suit. In a new build, the zone controller, wall touchpads and sensor cabling are easiest to run before the linings go on, alongside the rest of the new build electrical work.
Limitations
Zoning makes a well-designed ducted system better. It does not fix an undersized system, poorly insulated ducts, or a house that needs insulation. The room-by-room calculator gives preliminary loads, not a duct design. Damper positions, duct sizes and outlet selection come from a proper design for your home.
Next steps
- Enter your rooms in the room-by-room calculator and note which rooms you use at the same times.
- Read about ducted air conditioning with zoning and the switchboard upgrades a new ducted system sometimes needs.
- Request a quote for a new zoned system or for adding zones to an existing one.
Sources
This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.