Under the Healthy Homes heating standard, a rental must have one or more fixed heaters that can directly heat the main living room, each at least 1.5 kW, with enough total heating capacity to meet the minimum required for that room (Tenancy Services). A heat pump with a thermostat is an acceptable heater, and in most rentals it is the practical choice. The required capacity is worked out with the Tenancy Services heating assessment tool, the formula in the regulations, or a qualified specialist, not with a general sizing calculator.
This guide covers what the standard asks for, how heat pumps fit in, and common mistakes to avoid. It is general information: Tenancy Services is the authority, and its pages are linked throughout.
What the heating standard requires
From Tenancy Services:
- Fixed heating that can directly heat the main living room: the largest room used for general, everyday living, such as a lounge, family room or dining room.
- Each heater must be at least 1.5 kW and together they must meet the required heating capacity for that room.
- Heaters must not be open fires or unflued combustion heaters, such as a portable LPG bottle heater.
- Heat pumps and electric heaters must have a thermostat.
- If the required capacity is over 2.4 kW, electric heaters (other than heat pumps) cannot be used, except to top up qualifying existing heating installed before 1 July 2019.
The heating guidance explains that the main living room includes any space always open to it, such as an open-plan kitchen, hallway or stairwell. If a door can be closed between spaces, they do not need to be included.
Landlords who do not meet their obligations are in breach of the Residential Tenancies Act 1986 and may face penalties of up to $7,200, according to Tenancy Services. Level (BRANZ) notes the standards became mandatory for all private rental homes from 1 July 2025.
How the required capacity is worked out
Tenancy Services sets out three options:
- The heating assessment tool. It asks about location, build date, insulation, the living room layout and other features, and produces a report showing the minimum heating capacity. The report can help prove a rental meets the standard.
- The formula in the regulations (Schedule 2 of the Residential Tenancies (Healthy Homes Standards) Regulations 2019). Tenancy Services suggests a professional for complex layouts. There are two formulas: a newer one for modern dwellings (built to the 2008 Building Code, certain apartments, or homes upgraded to 2009 insulation and glazing standards) and the original one for everything else.
- A qualified specialist, such as a chartered professional engineer or someone with a relevant Level 7 qualification and at least 5 years of heating design experience. Records must be kept.
Tenancy Services notes that using an alternative tool or formula cannot guarantee the calculation will be correct under the standard. That includes ours.
Where the Plexus calculator fits, and where it does not
Our heat pump size calculator estimates the capacity needed for comfort, including cooling, using a different method and different design temperatures. It is useful for choosing a heat pump that tenants will be comfortable with. It does not certify Healthy Homes compliance and should not be used in place of the Tenancy Services tool.
A sensible approach for landlords:
- Run the Tenancy Services heating assessment tool and keep the report.
- Check our calculator too, if you want a comfort and cooling figure.
- Choose a heat pump whose label capacity meets or exceeds the Tenancy Services requirement. If our calculator gives a higher figure for comfort, consider sizing to that.
EECA's installation guide actually recommends using the Healthy Homes sizing method for living room heat pumps in any home, so it would meet the standard if the home were later rented.
Which heat pump capacity counts
The heating guidance says heat pumps sold in New Zealand must state a standardised heating capacity on the label, which is the capacity when tested at 7 °C. If the label shows a "Capacity (Range)" as well, use the nominal capacity, not the top of the range.
This is the figure you compare with the tool's result. It is the heating capacity (heat output), not the electrical power input, which is a much smaller number. See what size heat pump do I need? for the difference.
Worked example: reading the result
Suppose the Tenancy Services tool reports a required heating capacity of 5.2 kW for a main living room (an example figure, not a typical one).
| Option | Label heating capacity | Meets 5.2 kW? |
|---|---|---|
| High-wall heat pump, nominal 5.0 kW (range 1.2 to 6.5 kW) | 5.0 kW | No: use the nominal figure, not the range |
| High-wall heat pump, nominal 6.0 kW | 6.0 kW | Yes |
| Two fixed heaters: 3.6 kW heat pump installed after July 2019 plus 2.4 kW electric heater | 6.0 kW total | No: electric heaters cannot be used above 2.4 kW required capacity unless topping up pre-2019 heating |
| Ducted system with an outlet in the living room | Depends on design | Only if it delivers the required capacity directly to the main living room |
Existing heating and top-ups
Tenancy Services has specific rules for heaters installed before 1 July 2019. You may not need to add heating if each existing heater is over 2.4 kW, meets the general requirements, is not an electric heater (heat pumps are fine), and together they provide at least 80 % of the required capacity.
You can also top up existing pre-2019 heating with a fixed electric heater of 2.4 kW or less. Tenancy Services gives an example: a 3.6 kW heat pump installed before July 2019, where 6.0 kW is needed, can be topped up with a fixed 2.4 kW electric heater with a thermostat. When that heat pump needs replacing, the replacement must meet the full required capacity.
Exemptions
There are specific exemptions, for example where it is not reasonably practicable for a professional installer to fit a qualifying heater without substantial building work or damage, or where the property is a certified passive building. Landlords who do not own the whole building (for example an apartment owner) may be partially exempt but must still take all reasonable steps. Read the exemptions carefully before relying on one.
Installation, apartments and body corporates
- Heat pumps require a licensed electrician for installation, as the heating guidance notes.
- In a unit title, check body corporate rules about outdoor units on common property before booking an install. The heating guidance includes an example where a landlord must take all reasonable steps to get body corporate consent.
- Position the indoor unit so it genuinely heats the main living room. See where to install a heat pump.
Keeping it compliant
Anything installed to meet the standards must be kept in good working order. The heating guidance says tenants must clean accessible filters and keep outdoor units clear where easy to do, while maintenance needing technical knowledge or tools is generally the landlord's responsibility. An annual service record is useful evidence. See how often should a heat pump be serviced?
Do not forget the other standards
Heating is one of five standards. Rentals also need insulation, ventilation (openable windows and extractor fans in kitchens and bathrooms, see the ventilation standard), moisture ingress and drainage, and draught stopping. We can install compliant extractor fans through our home ventilation service.
How Plexus can help
We can install a heat pump that meets the capacity the Tenancy Services tool calculates, position it to heat the main living room, do the electrical work and provide the electrical Certificate of Compliance, and service it afterwards. Keep that certificate with your tenancy records; our guide to electrical certificates explains what it covers. We do not issue Healthy Homes compliance certificates: the compliance statement is the landlord's responsibility.
Next steps
- Run the Tenancy Services heating assessment tool and keep the report.
- Check comfort and cooling with our heat pump size calculator.
- See our Healthy Homes heating service, then request a quote and attach the Tenancy Services report.
Sources
- Tenancy Services: Heating standard
- Tenancy Services: Calculating heating capacity
- Tenancy Services: Heating assessment tool
- Tenancy Services: Healthy homes standards heating guidance (PDF)
- Tenancy Services: Healthy homes standards, what a landlord needs to know
- Tenancy Services: Ventilation standard
- EECA: Good Practice Guide, Heat Pump Installation (March 2022)
- Level (BRANZ): Active ventilation
This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.