The size you need is the heating capacity, in kilowatts of heat output, that your room loses on a cold night in your area, plus a small margin. For a single room, our heat pump size calculator works this out from the room's volume, insulation, region, windows and use. As an example, a 6 m x 5 m fully insulated, north-facing Auckland living room with a 2.4 m ceiling comes out at about 3.7 kW heating and 3.4 kW cooling.
The rest of this guide explains what goes into that number, how to read the result, and when a single unit is not the right answer.
Size means heat output, not power use
Every heat pump has two kinds of kW on its data sheet, and mixing them up is the most common sizing mistake.
- Capacity (thermal output): the heat it puts into the room, or the heat it removes when cooling. This is the "size" you see in model names and brochures.
- Power input (electrical): the electricity it draws to move that heat.
Because a heat pump moves heat rather than making it, output is several times the input. Level (BRANZ) puts typical domestic heat pumps at a coefficient of performance (COP) of 2 to 4.5 under optimum conditions. The example performance chart in EECA's installation guide shows a 6 kW rated model delivering 6.1 kW of heat at 7 °C outside while drawing 1.9 kW of electricity.
So when we say a room needs 3.7 kW, we mean 3.7 kW of heat, not 3.7 kW on your power bill.
The electrical side works from the power input, not the capacity. The manufacturer's installation manual states the supply and circuit protection the unit needs, and your electrician uses that to check the switchboard has room and the house can carry the extra load. If the board is old or full, see switchboard upgrades.
What decides the size
| Factor | Why it matters |
|---|---|
| Room volume | Heat loss scales with the volume of air and the area of walls, ceiling and floor. A 3 m stud needs more than a 2.4 m stud. |
| Insulation | An older, poorly insulated home loses heat far faster than a modern one, so it needs a bigger unit for the same room. |
| Climate | Heat pumps lose output as the outdoor temperature drops, so colder regions need more rated capacity. |
| Glazing and orientation | Large windows lose more heat in winter and let in more sun in summer. South-facing rooms get little winter sun. |
| Room use | Kitchens and living areas have more people and appliances, which adds to the summer cooling load. |
Level lists the same considerations for any sizing calculation: region and orientation, local conditions, window orientation, seasonal temperatures, insulation, occupants and solar gain.
How the Plexus calculator works it out
Our calculators run the same sizing engine Plexus uses in its trade software. For a single room, the method is:
- Volume x a watts-per-cubic-metre rate that depends on the insulation level you choose (new build 2016 or later, fully insulated, partially insulated, poorly insulated).
- Adjustments for large glazing and for south-facing rooms.
- A climate adjustment. The engine uses the winter design temperature for your region (27 NZ regions, from Mitsubishi Electric's NZ selector) and allows for the capacity a typical heat pump keeps at that temperature, relative to Auckland.
- A 2.5 % margin on top.
- A separate cooling calculation: heat gain through the building fabric at the summer design temperature, sun through the windows by orientation, and internal gains from people and appliances by room use.
A worked example: one room, four scenarios
These figures come straight from the single-room calculator. They are examples, not a quote or a design.
| Scenario | Heating | Cooling | Unit type suggested |
|---|---|---|---|
| Auckland living room, 6 x 5 m, 2.4 m ceiling, fully insulated, north-facing | 3.69 kW | 3.35 kW | High-wall |
| Same room, partially insulated, large glazing, east or west-facing | 4.67 kW | 5.23 kW | High-wall (cooling governs) |
| Same as the first row, but in Hamilton | 4.24 kW | n/a | High-wall |
| Auckland bedroom, 3.5 x 3.2 m, fully insulated, south-facing | 1.52 kW | 0.54 kW | High-wall |
A few things stand out:
- Insulation and glazing move the number more than people expect. The same floor area goes from 3.7 kW to 4.7 kW of heating.
- Cooling can be the bigger requirement. In the second row, a big east or west window means the summer load is higher than the winter one. The calculator flags this, because a unit chosen on heating alone may not cool the room.
- Climate matters. In Hamilton the engine assumes a colder winter design temperature, so the same room needs a larger rated unit.
How to read your result
The calculator shows a heading such as "Required capacity: 3.69 kW heating, 3.35 kW cooling", followed by a suggested unit type and notes.
- Match the rated capacities, not the model number. Look for a unit whose rated heating capacity is at or above the heating figure and whose rated cooling capacity is at or above the cooling figure. Model sizes vary between brands, so check the data sheet. Consumer NZ notes the number in a model code often reflects cooling capacity, which is a quick first check, not a substitute.
- Read the notes. If cooling governs, the note tells you to check the rated cooling figure specifically. In very cold regions it suggests asking about models that hold their capacity below zero.
- Unit type. Up to about 5 kW, a high-wall unit is the usual choice. Between 5 and 8 kW, a floor console is worth considering for heat distribution. Above 8 kW, the calculator suggests two units or a ducted system rather than one large wall unit.
- Show working. The result breaks down the volume, rates and adjustments so you can see why the number is what it is, and change an input if something looks wrong.
Too big or too small
EECA's installation guide is clear that both mistakes cost you:
- Undersized: the unit runs at full capacity too often, defrosts more, uses more energy and may not reach the temperature you want. EECA notes the extra running cost of an undersized unit generally outweighs the cost of going up a size.
- Significantly oversized: short cycling, draughts even at low fan speed, more noise, more wear and lower efficiency.
A slightly larger unit gives a safety margin. A much larger one does not make the room warm faster in any useful way. Mitsubishi Electric NZ makes a related point: setting 28 °C does not heat a room faster, it just uses more energy.
Capacity in cold weather
Rated capacity is measured in a lab at a mild outdoor temperature. Level explains that heat pumps can carry three heating ratings: H1 at 7 °C, H2 at 2 °C and H3 at -7 °C. On a frosty night, output can be well below the H1 figure.
EECA's guide gives a worked case: a room needing 5.6 kW at a design temperature of +1 °C. In its example chart, the 6 kW rated model only delivers 5.1 kW at 0 °C, so the 8 kW model is the right choice. Our calculator allows for this in its region adjustment, but final equipment selection should still be checked against the manufacturer's low-temperature performance data for the specific model.
Open-plan rooms and whole homes
A single-room calculation suits one room with a door. For an open-plan living, kitchen and dining area, enter the whole connected space. If the answer is above 8 kW, or the space is long and L-shaped, two smaller units often spread heat better than one big unit, a point EECA's guide also makes.
For several rooms, use the room-by-room calculator, which gives each room's heating and cooling load and the share of airflow each room would need in a ducted design. The whole-home calculator gives a quick ducted capacity from total floor area. See ducted vs high-wall heat pumps if you are weighing up the two.
Rentals are a separate calculation
If the heat pump is for a rental's main living room, the Healthy Homes heating standard sets the minimum capacity using its own method: the Tenancy Services heating assessment tool or the formula in the regulations. The Tenancy Services heating guidance says to compare that requirement with the heat pump's nominal capacity at 7 °C. Our calculator does not certify compliance. Use it for comfort sizing, and use the Tenancy Services tool for the legal minimum.
Limitations
The calculator is a preliminary estimate, not a heat-loss design. It does not model every wall, window and floor construction, unusual ceilings, very draughty rooms, or local microclimates such as a damp valley. It also cannot tell you where a unit will physically fit, which affects the choice as much as capacity does. A site visit confirms the room, the insulation and the install position before anything is ordered.
Next steps
- Size a single room with the heat pump size calculator.
- For several rooms or a ducted system, use the room-by-room calculator.
- Read about where to install a heat pump, then see our heat pump installation service.
- When you are ready, request a quote and include your calculator result.
Sources
This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.