A heat pump's running cost is its electrical input (kW) x the hours it runs x your electricity rate (c/kWh). The electrical input is much lower than the heat it delivers, because a heat pump moves heat rather than making it: EECA says the average heat pump in New Zealand puts out three times more heat than the power it consumes. So a heat pump delivering 3 kW of heat at that efficiency draws about 1 kW, which at a rate of 29 c/kWh costs about 29 cents an hour.
This guide shows you how to work the number out for your own unit, what pushes it up or down, and how to keep it low.
The two kW figures you need to know
- Heating or cooling capacity (kW, thermal output): the heat delivered into the room, or removed from it. This is the size on the brochure.
- Power input (kW, electrical): what the unit draws from your switchboard. This is what you pay for.
The ratio between them is the coefficient of performance (COP) for heating and the energy efficiency ratio (EER) for cooling:
Electrical input (kW) = heat output (kW) ÷ COP
Level (BRANZ) gives a typical COP of 2 to 4.5 for domestic heat pumps under optimum conditions, and a cooling EER of about 2.5 to 4.0. It also warns that lab figures are optimistic: a unit rated at COP 2.0 to 4.5 may achieve an overall operating COP of around 1.5 to 3.0 in practice.
Why outdoor temperature matters
A heat pump's output and efficiency both fall as it gets colder outside. EECA's installation guide includes an example performance chart for a 6 kW rated model:
| Outdoor temperature | Heat output | Electrical input | COP |
|---|---|---|---|
| 7 °C | 6.1 kW | 1.9 kW | 3.2 |
| 2 °C | 5.2 kW | 1.75 kW | 3.0 |
| 0 °C | 5.1 kW | 1.71 kW | 2.98 |
| -5 °C | 4.32 kW | 1.54 kW | 2.8 |
Source: EECA example chart, indoor 20 °C. Your model's chart will differ.
On a frosty morning the unit gives less heat for each unit of electricity, and it also pauses to defrost the outdoor coil. That is normal, but it is why winter bills vary from week to week.
Worked example 1: cost per hour at full output
Using the EECA example chart and an example tariff of 29 c/kWh (the MBIE-reported national average that Consumer NZ uses; your rate will differ):
- At 7 °C outside: 1.9 kW x 29 c = about 55 c per hour for 6.1 kW of heat.
- At 0 °C outside: 1.71 kW x 29 c = about 50 c per hour for 5.1 kW of heat.
This is the cost while the unit is running flat out, for example warming a cold room. Once the room reaches the set temperature, an inverter heat pump slows its compressor down and the input drops well below these figures.
Worked example 2: a rough winter estimate
This is an illustration with assumed numbers, not a prediction for your home.
| Assumption | Example value |
|---|---|
| Average heat needed once the room is warm | 2 kW |
| Hours used per day | 6 (evenings) |
| Real-world average COP | 3 |
| Heating days per year | 120 |
| Electricity rate | 29 c/kWh |
Daily electricity: 2 kW ÷ 3 x 6 h = 4 kWh. Daily cost: 4 x 29 c = about $1.16. Over 120 days: about 480 kWh, roughly $139 a year.
For comparison, a plug-in electric heater delivering the same 2 kW of heat draws about 2 kW of electricity (Consumer NZ notes plug-in heaters produce slightly less than 1 kW of heat per kW of electricity). That is 12 kWh a day, about $3.48 a day at the same rate, or around three times as much.
To use your own numbers, swap in your tariff from your power bill, the hours you actually run it, and a COP from your model's data sheet (use a conservative figure).
What the national guides say about typical costs
- Consumer NZ: depending on usage, a very large heat pump (10 kW or more) might cost $1,000 per year to keep you warm, while a small one (2.5 kW) can cost below $200.
- EECA: heat pumps are about a quarter of the cost to run of bar and column heaters, and around a third of the cost of heating with gas.
- Level (BRANZ): in a BRANZ study of 160 households with heat pumps, more people said their energy costs had increased than fallen, largely because homes were kept warmer. Heat pumps do not replace the need for insulation.
Cooling costs
Consumer NZ's air con guide uses the same method: cooling capacity ÷ EER x your rate. Its example is an 8 kW unit with an EER of 4, which draws 2 kW, or about 58 c per hour at 29 c/kWh. Consumer says cooling at full capacity costs on average about 7 % less than heating, and much less once the room is down to temperature.
Using the Energy Rating Label
New heat pumps must display an Energy Rating Label. Level explains that the zoned label gives a heating star rating out of 10: more stars means more efficient than other models of the same size. The label also shows an annual energy figure in kWh, and Consumer NZ suggests multiplying it by your tariff for a comparable running cost. Only compare labels between models of similar capacity.
Your tariff matters as much as the unit
Your bill has two parts: a daily fixed charge and a per-kWh rate. Only the per-kWh part changes with heat pump use. EECA notes time-of-use plans with cheaper off-peak power can suit households with electric heating, and points to Billy, the Electricity Authority's independent plan comparison service.
How to keep running costs down
From EECA's efficiency advice and its installation guide:
- Set 18 to 21 °C. At least 18 °C to fight damp and mould, below 21 °C to save power.
- Use the timer to start shortly before you wake or get home. Do not run it 24/7.
- Use Heat mode, not Auto. EECA's guide says Auto can switch between heating and cooling as the temperature fluctuates, wasting energy.
- Set the fan to Auto. Low or Quiet reduces heating output and efficiency.
- Close doors to rooms you are not using, and use curtains and draught stoppers.
- Clean the filter. EECA suggests once a month during winter. Clogged filters make the unit work harder.
- Keep the outdoor unit clear of plants and clutter so air can flow.
- Get it serviced. See how often a heat pump should be serviced.
Sizing affects running cost
An undersized heat pump runs at full output for longer, defrosts more and uses more energy. EECA's guide notes the extra running costs of an undersized unit generally outweigh the cost of going one size up. A badly oversized unit short cycles and wastes energy too. Our heat pump size calculator gives you the capacity to aim for. It does not estimate running cost, but getting the size right is the first step to a sensible bill.
Ducted systems and zoning
A ducted system can heat the whole house, so it can use more electricity in total than one wall unit heating one room. Consumer NZ notes ducted systems are slightly less efficient because of heat loss from the ducts. Zoning lets you heat or cool only the rooms in use, which is where most of the saving comes from. See how ducted zoning works.
Limitations
Every number here is either from a cited national source or clearly marked as an assumption. Your real cost depends on your house, your habits, your power plan and the specific model. If you have a smart meter, your retailer's usage data is the most accurate way to see what your heat pump is actually using.
Next steps
- Size your room with the heat pump size calculator, or the whole house with the room-by-room calculator.
- Ask us to compare efficient models for your home through our heat pump installation service.
- Request a quote.
Sources
- EECA: Choose an efficient heat pump for your home
- EECA: Use your heat pump efficiently
- EECA: Good Practice Guide, Heat Pump Installation (March 2022)
- Level (BRANZ): Heat pumps
- Consumer NZ: Heat pump buying guide
- Consumer NZ: The cost of using air con in summer
- Billy (Electricity Authority power plan comparison)
This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.