Heat pump error codes and common faults: what is normal and what is not

Flashing lights, error codes, no heat, dripping water or odd noises? Learn which heat pump behaviour is normal, the safe checks you can make, and when to call.

By Plexus ElectricalPublished Updated 6 min read

Many things that look like faults are normal: a heat pump that stops heating for a few minutes on a cold morning is usually defrosting, one that will not restart straight away is usually in a built-in restart delay, and white "steam" from the outdoor unit in winter is vapour from defrosting. A genuine fault usually shows as a flashing operation light or an error code, water dripping from the indoor unit, a breaker that keeps tripping, or a unit that runs but never reaches temperature. Error codes are specific to each brand and model, so your operating manual is the authority on what a code means.

This guide covers what is normal, the safe checks you can make, and when to call a technician.

First: is it actually a fault?

These behaviours are listed as normal in manufacturers' manuals, including Mitsubishi Electric's operating instructions for one of its common high-wall ranges:

What you notice Usual explanation
Heating stops for a few minutes in cold weather Defrost. The outdoor unit is melting ice off its coil. Mitsubishi says this can take about 2 to 10 minutes.
Cold or no air when heating starts The unit is warming up, or defrosting. It waits rather than blowing cold air.
Will not start for about 3 minutes after switching back on Restart protection for the compressor. Wait.
White "smoke" from the outdoor unit in winter Vapour from defrosting, not smoke.
Water dripping from the outdoor unit Normal in heating (condensation and melted ice) and in cooling.
Mist from the indoor unit in cooling Cool air condensing moisture in the room.
Cracking, hissing or water-flowing sounds Plastic expanding and contracting, or refrigerant moving.
Outdoor fan stopping and starting Normal control behaviour in some conditions.
Unit restarts by itself after a power cut Auto restart function on many models.
Vanes move to horizontal during heating Automatic, when airflow temperature is low or during defrost.

Mitsubishi Electric NZ's FAQ also explains that Dry mode does not heat, so a unit left in Dry will not warm the room. And setting 28 °C does not heat the room faster.

Safe checks you can make

These are the checks Plexus is happy for any homeowner to do. Do not open covers, remove panels or touch wiring or refrigerant pipes.

  1. Remote and mode. Check the remote batteries, that it shows the right mode (Heat, not Cool, Dry, Fan or Auto) and a sensible temperature. EECA suggests 18 to 21 °C for heating. Check no timer or Night/Quiet mode is limiting it.
  2. Filters. Clogged filters reduce airflow and heating. Clean them following your manual. EECA suggests monthly in winter.
  3. Fan setting. Low or Quiet fan reduces output. EECA recommends Auto fan.
  4. Doors and windows. An open door or window to the rest of the house can stop a room reaching temperature.
  5. Outdoor unit. Make sure it is not blocked by plants, leaves, a cover or stored items, and that ice is clearing during defrost.
  6. Circuit breaker. Check whether the heat pump's breaker at the switchboard has tripped. You can switch it back on once. If it trips again, leave it off and call us.
  7. Power to the house. If other things are off too, the problem may be the supply, not the heat pump.

If those checks do not fix it, it is time for a technician.

Error codes and flashing lights

Every manufacturer uses its own system. Some show a code on the remote or wall controller, some flash a light on the indoor unit in a pattern, and ducted and commercial controllers often show a code with a unit number. A flashing light is not always a fault: on some models it is a Wi-Fi or standby indicator. Mitsubishi's manual lists a blinking operation indicator lamp as one of the cases where you should stop using the unit and contact your dealer. EECA's installation guide tells installers to refer to the unit handbook to identify faults shown by flashing LEDs.

Because the same code can mean different things on different brands, we have not listed codes here. Generic online lists are often for overseas models and can be misleading.

What to record before you call:

  • the brand and model number of the indoor and outdoor units (on the nameplate or in the manual);
  • the exact code shown, or the flash pattern (count the flashes and which light, and how long the pause is);
  • what the unit was doing when it happened (heating, cooling, just switched on);
  • whether the breaker has tripped;
  • a photo of the display or the lights.

This helps a technician bring the right parts and diagnose it faster.

Common faults and likely causes

Symptom Possible causes What to do
Runs but room never warms Dirty filter, wrong mode, undersized unit, blocked outdoor unit, low refrigerant Do the safe checks; then book a repair visit
Water dripping from the indoor unit Blocked condensate drain, poor drain fall, failed condensate pump Switch off and call. Mitsubishi's manual lists indoor water leaks as a reason to stop using the unit.
Ice that does not clear from the outdoor unit Blocked airflow, defrost fault, low refrigerant Check for obstructions; if it persists, call
Breaker trips repeatedly Electrical fault in the unit or circuit Leave it off and call. Do not keep resetting it.
Unusual noise (grinding, rattling, squealing) Worn fan bearings, loose panel, debris, vibration Call. EECA's guide says get it checked if the sound changes.
Musty smell Dirty filter or coil, mould in the drain tray Clean filters; book a service
Remote does nothing Flat batteries, remote fault, power off Replace batteries, check power and breaker
Ducted: some rooms cold Closed zone, damper fault, disconnected or crushed duct, dirty return filter Check zone settings and return-air filter; then call

Mitsubishi's manual also lists abnormal sounds, frequent breaker trips and any refrigerant leak as reasons to stop using the unit and call.

What not to do

  • Do not top up refrigerant or open the refrigerant circuit. Refrigerant work needs certified technicians, and a low charge means a leak that needs repairing.
  • Do not open the electrical covers or rewire anything. Electrical work must be done by a licensed electrical worker, with only limited homeowner exemptions: see WorkSafe's guidance.
  • Do not spray water into the indoor unit, and do not spray the outdoor unit's fan motor or wiring. EECA's guide warns against this.
  • Do not keep resetting a breaker that trips.

Repair or replace?

EECA lists a typical lifespan of about 15 years for heat pumps. An older unit with a major fault (compressor, refrigerant leak in the coil, main control board) may cost more to repair than it is worth, especially if parts are hard to get. Newer units are often more efficient too. A technician can give you a repair quote and a replacement option so you can compare. If replacing, re-check the size: see what size heat pump do I need?

Preventing faults

Most of the faults above are less likely with clean filters, a clear outdoor unit and a regular service. See how often should a heat pump be serviced?

Next steps

Sources

  1. Mitsubishi Electric NZ: MSZ-LN operating instructions, When you think that trouble has occurred (PDF)
  2. Mitsubishi Electric NZ: Common heat pump questions
  3. EECA: Good Practice Guide, Heat Pump Installation (March 2022)
  4. EECA: Use your heat pump efficiently
  5. WorkSafe: Doing your own electrical work

This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.

FAQ

Frequently asked questions

What does a flashing light on my heat pump mean?

It depends on the brand and model. On some units a flashing light is a normal status signal, for example during Wi-Fi pairing or on a standby unit in a multi-room system. On others, a blinking operation lamp is a fault indicator. Your operating manual explains your unit's lights. If it shows a fault, note the pattern and call a technician.

Why does my heat pump blow cold air in heating mode?

Most often because it is defrosting the outdoor unit, which is normal in cold, damp weather. EECA's installation guide says this usually only takes a few minutes. If it happens constantly or the room never warms up, get it checked.

Is it safe to reset my heat pump at the switchboard?

Checking whether a breaker has tripped and switching it back on once is a reasonable homeowner check. If it trips again, leave it off and call an electrician or heat pump technician. Repeated tripping is a sign of a fault.

Can I top up the refrigerant myself?

No. Refrigerant handling requires certification, and low refrigerant means there is a leak that needs finding and repairing. Leave it to a qualified technician.