Skip to content
Plexus Electrical

Electrical

Home lighting design guide: layers, levels and switching

A practical lighting design guide for NZ homes: general, task and accent lighting, lux levels by activity, LED choices, downlights, switching and outdoors.

By Plexus ElectricalPublished 5 min read

Good home lighting design layers three kinds of light (general, task and accent), sets the brightness to suit what each area is used for, and puts the switches where people actually walk. For most NZ homes that means LED fittings throughout, warm white in living areas, brighter focused light over benches and desks, and controls such as dimmers and sensors where they save energy or make life easier. This guide explains each step so you can brief an electrician or check a lighting plan.

Start with daylight

Level (BRANZ) says homes should make the most of natural light during the day, with artificial light added where natural light is unavailable or inadequate, and for specific tasks. When you plan lighting, note which rooms get good daylight and which rely on artificial light most of the time. A south-facing hallway or an internal bathroom needs more thought than a sunny living room.

The three layers of lighting

Level describes three types of lighting:

Layer What it does Typical examples
General Low-level, all-over light for a space Downlights, ceiling fittings, cove lighting
Task Higher light on a specific area Under-cabinet lights over benches, desk lamps, mirror lights
Accent Highlights decorative or dramatic features Spotlights on artwork, wall washers, garden uplights

A room lit only by the general layer can feel flat. Two or more layers on separate switches let you choose the mood.

How bright should each area be?

Level (BRANZ) gives these guide levels:

Activity Suggested level
General household activity (vacuuming, washing) 150 to 200 lux
Focused activity (reading, studying, working on a car) 300 to 500 lux
Concentrated activity (fine detail sewing) 800 to 1000 lux or more

Level suggests adjusting upward where there is little reflected light, low contrast, no windows, or older occupants, and downward for short tasks. It also notes that light-coloured, glossier surfaces reflect more light, so a white kitchen needs less light than a dark one.

The Building Code sets minimums well below these comfort levels. Level notes that clause G8 requires 20 lux at floor level whenever a room is occupied. Meeting the minimum is not the same as a comfortable room.

Choosing lamps and fittings

LEDs as the default

Level (BRANZ) says "LEDs should be the default lighting in homes." EECA states LEDs use up to 85 % less electricity than incandescent or halogen bulbs and are rated at around 30,000 hours, compared with 2,000 hours for incandescent bulbs. For new builds and major renovations, Level suggests dedicated LED fittings that manage heat well.

Two practical points from Level and EECA:

  • LEDs last longest with unrestricted air movement, so avoid fully enclosed fittings such as some porch globes.
  • LEDs handle frequent switching well, which suits toilets and wardrobes.

Colour temperature

EECA says warm white is the more comfortable choice for homes, and cool white suits spaces where contrast matters, such as workshops and garages. Whatever you choose, keep it consistent within a room, because warm and cool fittings side by side tend to look patchy.

Downlights and insulation

Downlights are popular, but the fitting type matters. Level (BRANZ) lists three problems with older recessed downlights: insulation must be kept clear of them to prevent overheating, the holes let heat escape and undermine ceiling insulation, and moist air escaping into the roof space can cause condensation and mould. BRANZ recommends replacing older downlights with surface-mounted lights or IC or IC-F rated downlights, which can be covered by insulation. EECA adds that for recessed downlights you should replace the whole fitting, not just the bulb, because most of the savings come from reducing heat loss into the ceiling.

Coordinate with heating, cooling and smoke alarms

Ceilings are crowded. Downlights compete for space with smoke alarms, ducted heat pump outlets and return grilles, extract fans and ceiling joists. In a home with ducted air conditioning, lay out the lighting and the duct outlets on the same plan, so lights do not end up off-centre or in the airflow path. This is one of the reasons we prefer to design electrical and HVAC together.

Switching and controls

Level (BRANZ) recommends:

  • switches for general lighting at room entry and exit points;
  • two-way or three-way switching where a room has more than one entrance, and for stairs;
  • task and accent switches next to the task area, or grouped on a separate panel;
  • separate control for each lighting group, because one switch for every light in a room wastes energy.

Dimmers, sensors and timers

  • Dimmers save energy and extend lamp life by reducing output (Level). With LEDs, check the lamp is marked dimmable and that the lamp and dimmer are designed to work together.
  • Motion sensors switch lights on when someone enters and off after they leave. Level recommends models with a daylight sensor or timer and a manual override.
  • Delay timers suit rarely used spaces such as toilets and storerooms, though Level notes lights that switch off without warning can be a safety risk.
  • Smart lighting can be scheduled, run randomised "holiday" routines and coordinate with security. See smart home automation.

Outdoor lighting

Level notes outdoor lighting may be needed for safe passage along paths and steps after dark and to make decks usable, and that excessive outdoor lighting can disturb neighbours and cause light pollution. Sensor lights at entrances and along paths give light when it is needed without lighting the street all night. NZ Police advice includes getting sensor lights fitted as part of home security; see our home security options guide.

A simple room-by-room starting point

Room General Task Accent or extras
Kitchen Downlights or ceiling fittings Under-cabinet strips over benches, pendants over an island Toe-kick or shelf lighting
Living Dimmable downlights or ceiling fittings Reading lamps beside seating Wall washers, artwork lights
Bedrooms Ceiling fitting or downlights Bedside lights on switches at the bed Wardrobe lighting
Bathroom Downlights rated for the location Mirror lighting Night light on a sensor
Hallways and stairs Downlights or wall lights Not usually needed Step lights, two-way switching
Outdoors Entry lighting Sensor lights on paths and driveway Garden uplighting

Next steps

A lighting plan is easiest to get right before the prewire in a new build, or while ceilings are open in a renovation. Plexus offers lighting design and installation as part of our electrical design service. Send us your plans and request a quote.

Sources

  1. Level (BRANZ): Lighting design
  2. Level (BRANZ): Appropriate lighting levels
  3. Level (BRANZ): Lamp selection
  4. Level (BRANZ): Switches, sensors, dimmers and timers
  5. EECA: LED lighting
  6. NZ Police: Keep your home and vehicle secure (January 2020)

This guide is general information for New Zealand homes, not advice for your specific property. For a recommendation that accounts for your house, ask us.

FAQ

Frequently asked questions

Should I use warm white or cool white LEDs?

EECA says warm white is the more comfortable choice for homes, and cool white suits spaces where contrast matters, such as workshops and garages. Many people use warm white throughout the living areas and bedrooms and keep cooler light for the garage.

How many downlights do I need?

There is no fixed number. It depends on the room size, ceiling height, the light output and beam of the fittings, the colour of the surfaces and what the room is used for. A lighting plan works from the activity in each area. Level (BRANZ) suggests around 150 to 200 lux for general household activity and 300 to 500 lux for focused tasks such as reading.

Can insulation go over downlights?

Only if they are rated for it. Level (BRANZ) notes that insulation must be kept clear of older downlights, and BRANZ recommends replacing them with surface-mounted lights or IC or IC-F rated downlights, which can be covered by insulation.

Are dimmers worth it with LEDs?

They can be. Level (BRANZ) notes dimmers save energy and extend lamp life by reducing output. With LEDs, the lamp must be dimmable and the dimmer and lamp need to work together, so choose them as a pair.

Get a quote

Tell us about your project.

Whether it is one power point or a fifteen-home development, the quickest way to an accurate quote is a few details and, if you have them, photos or plans.

Call 021 210 5934Request a quote